Multi-Toxins

General information on multi mycotoxin testing

Mycotoxins generally co-occur in different commodities. It is not unusual to find different trichothecenes in one product, sometimes even in combination with zearalenone. Other commodities might contain both aflatoxin and ochratoxin or aflatoxin and fumonisin.

With the development of multi mycotoxin anayltical methods on HPLC or LC-MS/MS the need for an effective multi mycotoxin clean-up arose.

Multi mycotoxin testsystems from R-Biopharm

We offer different analytical platforms for the analysis of multiple mycotoxins as well as standards and reference materials.

AO ZON PREP®

Intended use:

Multi-mycotoxin immunoaffinity columns for simultaneous detection of aflatoxin B1, B2, G1, G2, ochratoxin A and zearalenone in a wide range of commodities in conjunction with HPLC or LC-MS/MS.

General Information:

The procedure is based on monoclonal antibody technology, which makes the test highly specific, sensitive, rapid and simple to perform. Improved clean-up and concentration of toxins from complex food matrices results in reduced chromatography interference and lower detection limits.

Specifications
Art. No. P112 / P112B
Test Format 10 wide format immunoaffinity columns (P112).
50 wide format immunoaffinity columns (P112B).
Sample Preparation The columns contain a gel suspension of monoclonal antibody specific to the toxins of interest. Following extraction of the toxins the sample extract is filtered, diluted and passed through the immunoaffinity column. Any toxins which are present in the sample are retained by the antibody within the gel suspension. The column is washed to remove unbound material and the toxins are released from the antibody following elution with solvent. The eluate is collected and injected prior to analysis by HPLC.
Detection Limit LOD: B1 – 0.031 ng/ml
B2 – 0.015 ng/ml
G1 – 0.015 ng/ml
G2 – 0.007 ng/ml
OTA – 0.05 ng/ml
ZON – 1.67 ng/ml
Cross Reactivity Ochratoxin B (OTB), α-Zearalenol (α-ZOL), ß-Zearalenol (ß-ZOL), Zearalanone (ZAN), α-Zearalanol (α-ZAL) and Zeranol.
Shelf life 2 years at 2 – 8 °C (or 12 months at 21 – 25 °C).
Sensitivity Low % CV, excellent recoveries, capacity and limit of detection exceeds EU Legislation and CEN / AOAC requirements.
Rapid Only one extraction and a single column clean up required taking as little as 20 minutes prior to detection by HPLC. Simultaneous detection of total aflatoxins and ochratoxin A in one HPLC run while zearalenone is detected in a second HPLC run. Analysis of all toxins can be performed in a single LC-MS/MS run.
Robust Can be stored at room temperature.
Reliable Uses monoclonal antibodies to selectively isolate and concentrate aflatoxins B1, B2, G1, G2 , ochratoxin A and zearalenone.
Adaptable The columns are suitable for testing a wide range of commodities.
Extraction solvents Methanol or acetonitrile.
Additional Information Cost Effective: No need for separate extractions and clean-up, saving time and money.
Email Link biotica@otenet.gr

Trichothecene P Column

Intended use:

Solid phase clean-up columns for the purification of trichothecenes from cereals.

General Information:

TRICHOTHECENE P Columns can be used for the simultaneous detection of type A and B trichothecenes by GC. The columns reduce background interference therefore producing better chromatography and improving accuracy of results.

Specifications
Art. No. P51
Test Format 30 solid phase clean-up columns.
Sample Preparation The toxins are extracted from the sample, filtered and passed through the solid phase clean-up column.The clean-up columns can be used in conjunction with GC for the analysis of pigmented samples.
Detection Limit 50 ng/ml.
Cross Reactivity T-2, HT-2, diacetoxyscirpenol, neosolaniol, fusarenon X, 3-acetyl DON, 15-acetyl DON, DON, nivalenol.
Shelf life 2 years at 21 – 25 °C.
Rapid Clean-up in 30 minutes prior to detection by GC.
Robust Can be stored at room temperature.
Reliable An effective clean-up system producing cleaner chromatography and increased accuracy.
Adaptable The columns are suitable for testing a wide range of cereal samples.
Extraction solvents Acetonitrile.
Email Link biotica@otenet.gr

Trichothecene EP Column

Intended use:

Solid phase clean-up columns for the purification of trichothecenes from animal feed.

General Information:

PuriTox Trichothecene Plus can be used for the simultaneous detection of type A and B trichothecenes by GC. The columns reduce background interference therefore producing better chromatography and improving accuracy of results.

Specifications
Art. No. P53
Test Format 30 solid phase gravity flow clean-up columns.
Sample Preparation The toxins are extracted from the sample, filtered and passed through the solid phase clean-up column.The clean-up columns can be used in conjunction with GC for the analysis of pigmented samples.
Detection Limit 50 ng/ml.
Cross Reactivity T-2, HT-2, diacetoxyscirpenol, neosolaniol, fusarenon X, 3-acetyl DON, 15-acetyl DON, DON, nivalenol.
Shelf life 2 years at 21 – 25 °C.
Rapid Clean-up in 30 minutes prior to detection by GC.
Robust Can be stored at room temperature.
Reliable An effective clean-up system producing cleaner chromatography and increased accuracy.
Adaptable The columns are suitable for testing a wide range of animal feed samples.
Extraction solvents Acetonitrile.
Email Link biotica@otenet.gr

DZT MS-PREP®

Intended use:

Multi-mycotoxin immunoaffinity columns for simultaneous detection of deoxynivalenol, zearalenone, T-2 and HT-2 in a wide range of commodities in one LC-MS/MS run.

General Information:

The procedure is based on monoclonal antibody technology, which makes the test highly specific, sensitive, rapid and simple to perform. Improved clean-up and concentration of toxins from complex food matrices results in reduced chromatography interference and lower detection limits.

Specifications
Art. No. P73 / P73B
Test Format 10 narrow format immunoaffinity columns (P73).
50 narrow format immunoaffinity columns (P73B).
Sample Preparation The columns contain a gel suspension of monoclonal antibody specific to the toxins of interest. Following extraction of the toxins the sample extract is filtered, diluted and passed through the immunoaffinity column. Any toxins which are present in the sample are retained by the antibody within the gel suspension. The column is washed to remove unbound material and the toxins are then released by the antibody following elution with solvent. The eluate is collected prior to analysis by LC-MS/MS.
Detection Limit LOD: DON – 0.1 ng/ml
ZON – 0.05 ng/ml
T-2 – 0.05 ng/ml
HT-2 0.05 ng/ml
Cross Reactivity 3-acetyl DON, α-Zearalenol (α-ZOL), ß-Zearalenol (ß-ZOL), Zearalanone (ZAN), α-Zearalanol (α-ZAL) and Zeranol.
Shelf life 18 months at 2 – 8 °C (or 12 months at 21 – 25 °C).
Sensitivity Low % CV, excellent recoveries and limit of detection complies with EU Legislation.
Rapid Only one extraction and a single column clean-up required taking as little as 20 minutes prior to detection by LC-MS/MS. Simultaneous detection of deoxynivalenol, zearalenone, T-2 and HT-2 in one LC-MS/MS run.
Robust Can be stored at room temperature.
Reliable Uses monoclonal antibodies to selectively isolate and concentrate deoxynivalenol, zearalenone, T-2 and HT-2.
Adaptable The columns are suitable for testing a wide range of commodities.
Extraction solvents Methanol and Acetonitrile.
Additional Information Cost Effective: No need for three separate analyses, saving time and money.Improved Clean-Up: Reduces interference and therefore the need to use matrix matched standards.
Email Link biotica@otenet.gr

AFLAOCHRA PREP®

Intended use:

Multi-mycotoxin immunoaffinity columns for simultaneous detection of aflatoxin B1, B2, G1, G2 and ochratoxin A in a wide range of commodities in one HPLC run.

General Information:

The procedure is based on monoclonal antibody technology, which makes the test highly specific, sensitive, rapid and simple to perform. Improved clean-up and concentration of toxins from complex food matrices results in reduced chromatography interference and lower detection limits.

Specifications
Art. No. P89 / P89B
Test Format 10 narrow format immunoaffinity columns (P89).
50 narrow format immunoaffinity columns (P89B).
Sample Preparation The columns contain a gel suspension of monoclonal antibody specific to the toxins of interest. Following extraction of the toxins the sample extract is filtered, diluted and passed through the immunoaffinity column. Any toxins which are present in the sample are retained by the antibody within the gel suspension. The column is washed to remove unbound material and the toxins are released from the antibody following elution with solvent. The eluate is collected and injected prior to analysis by HPLC.
Detection Limit LOD: B1 – 0.031 ng/ml
B2 – 0.015 ng/ml
G1 – 0.015 ng/ml
G2 – 0.007 ng/ml
OTA – 0.05 ng/ml
Cross Reactivity Ochratoxin B (OTB)
Shelf life 18 months at 2 – 8 °C (or 12 months at 21 – 25 °C).
Sensitivity Low % CV, excellent recoveries, capacity and limit of detection exceeds EU Legislation and CEN / AOAC requirements.
Rapid Only one extraction and a single column clean up required taking as little as 20 minutes prior to detection by HPLC. Simultaneous detection of total aflatoxins and ochratoxin A in one HPLC run.
Robust Can be stored at room temperature.
Reliable Uses monoclonal antibodies to selectively isolate and concentrate aflatoxins B1, B2, G1, G2 and ochratoxin A.
Adaptable The columns are suitable for testing a wide range of commodities.
Extraction solvents Methanol.
Additional Information Cost Effective: No need for two separate analyses, saving time and money.
Email Link biotica@otenet.gr

PuriTox Trichothecene Plus

Intended use:

Solid phase clean-up columns for the purification of trichothecenes from animal feed.

General Information:

PuriTox Trichothecene Plus can be used for the simultaneous detection of type A and B trichothecenes by GC. The columns reduce background interference therefore producing better chromatography and improving accuracy of results.

Specifications
Art. No. TC-C210
Test Format 25 solid phase gravity flow clean-up columns
Sample Preparation The toxins are extracted from the sample, filtered and passed through the solid phase clean-up column.The clean-up columns can be used in conjunction with GC for the analysis of pigmented samples.
Detection Limit 50 ng/ml
Cross Reactivity T-2, HT-2, diacetoxyscirpenol, neosolaniol, fusarenon X, 3-acetyl DON, 15-acetyl DON, DON, nivalenol
Shelf life 3 years.
Rapid Clean-up in 30 minutes prior to detection by GC
Robust Can be stored at room temperature
Reliable An effective clean-up system producing cleaner chromatography and increased accuracy.
Adaptable The columns are suitable for testing a wide range of cereal samples.
Extraction solvents Acetonitrile.
Email Link biotica@otenet.gr

PuriTox MultiToxin

Intended use:

Solid phase clean-up columns for the purification of aflatoxins and zearalenone from cereals.

General Information:

PuriTox MultiToxin columns can be used for the simultaneous detection of aflatoxins and zearalenone by HPLC or GC. The columns reduce background interference therefore producing better chromatography and improving accuracy of results.

Specifications
Art. No. TC-M160
Test Format 25 solid phase syringe format clean-up columns
Sample Preparation The toxins are extracted from the sample, filtered and passed through the solid phase clean-up column.The clean-up columns can be used in conjunction with HPLC or GC for the analysis of pigmented samples.
Detection Limit Aflatoxin – 1 ng/ml
Zearalenone – 50 ng/ml
Shelf life 3 years at 21 – 25 °C
Rapid Clean-up in 30 minutes prior to detection by HPLC or GC.
Robust Can be stored at room temperature.
Reliable An effective clean-up system producing cleaner chromatography and increased accuracy.
Adaptable The columns are suitable for testing a wide range of cereal samples.
Extraction solvents Acetonitrile and Methanol.
Email Link biotica@otenet.gr

PuriTox Trichothecene

Intended use:

Solid phase clean-up columns for the purification of trichothecenes from cereals.

General Information:

PuriTox Trichothecene can be used for the simultaneous detection of type A and B trichothecenes by GC. The columns reduce background interference therefore producing better chromatography and improving accuracy of results.

Specifications
Art. No. TC-T220
Test Format 25 solid phase syringe format clean-up columns.
Sample Preparation The toxins are extracted from the sample, filtered and passed through the solid phase clean-up column.The clean-up columns can be used in conjunction with GC for the analysis of pigmented samples.
Detection Limit 50 ng/ml.
Cross Reactivity T-2, HT-2, diacetoxyscirpenol, neosolaniol, fusarenon X, 3-acetyl DON, 15-acetyl DON, DON, nivalenol
Shelf life 3 years at 21 – 25 °C.
Rapid Clean-up in 30 minutes prior to detection by GC.
Robust Can be stored at room temperature.
Reliable An effective clean-up system producing cleaner chromatography and increased accuracy.
Adaptable The columns are suitable for testing a wide range of cereal samples.
Extraction solvents Acetonitrile.
Email Link biotica@otenet.gr

Mycotoxins

Mycotoxin Standards
Aflatoxin
Citrinin
DON
Fumonisin
Multi-Toxins
Ochratoxin
Patulin
Reference Materials
T-2 Toxin / HT-2 toxin
Trichothecenes
Zearalenone
Accessories